Aeroqual AQS 1 Urban Air Quality Monitoring System

In stock

296166

Aeroqual AQS 1 Urban Air Quality Monitoring System offers simultaneous measurement of multiple particle fractions, including TSP, PM10, PM4, PM2.5, and PM1 also measures nitrogen dioxide (NO2), ozone (O3), carbon monoxide (CO), hydrogen sulfide (H2S), and sulfur dioxide (SO2). This Outdoor Air Monitoring System device records and reports data in 1-minute intervals with user-selectable averaging, ensuring highly accurate results.

Applications: Urban Air Quality Monitoring, National air monitoring networks, Industrial Emissions Monitoring Roadside air monitoring, Environmental impact assessments, Industrial perimeter monitoring, Research and consultancy projects, Short term hot spot monitoring.

Aeroqual AQS 1 Urban Air Quality Monitoring System measures and reports data in 1-minute intervals with user-selectable averaging, allowing data access and alert settings via any wireless device. This Online Outdoor air Monitor robust, weatherproof enclosure with solar shielding makes it suitable for use in various conditions. This outdoor air quality monitor provides valuable insights into pollutant activity at local and micro scales. The AQS 1 is a compact ambient air quality monitor designed to target specific pollutants in urban environments.

Features of Aeroqual Urban Air Quality Monitoring System :

  • It comes with the communication of Standard: WIFI, Ethernet (LAN). Optional: Cellular IP 4G LTE with a built-in high-gain antenna.
  • This Urban air quality monitor can be installed on Pole, tripod and wall mounting brackets included.
  • It comes with IP65 protection class with GRP cabinet with an aluminum solar shield and a built-in temperature and humidity sensor.
Gas module Range Display
Resolution
Noise
Zero; Span
% of reading
Lower Detection
Limit (2σ)
Precision Linearity
(% of FS)
Drift 24 hour
Zero;
Span % of FS
Ozone O3 0-500
ppb
0.1 ppb <1 ppb;
1%
<1 ppb 2% of reading
or 2 ppb
1% 1 ppb;
0.2%
Nitrogen dioxide
NO2
0-500
ppb
0.1 ppb <1 ppb;
1%
<1 ppb 2% of reading
or 2 ppb
1.50% 1 ppb;
0.2%
Carbon
Monoxide CO
0-25
ppm
0.001ppm 0.02 ppm;
1%
0.04 ppm 3% of reading
or 0.05 ppm
1% 0.14 ppm;
2%
VOC (Low range) 0-500
ppb
0.1 ppb <1 ppb;
1%
<1 ppb 2% of reading
or 1 ppb
1% 1 ppb;
1%
VOC (High range) 0-30 ppm 0.01ppm <0.1 ppm;
1%
<0.1 ppm 2% of reading
or 0.05 ppm
2% 0.1 ppm;
1%
Hydrogen Sulfide
H2S
0-10,000
ppb
0.1 ppb 1 ppb;
0.1%
2 ppb 1% of reading or
3 ppb
0.50% <1 ppb;
<0.5%
Sulfur Dioxide
SO2
0-10,000
ppb
0.1 ppb 1 ppb;
0.02%
2 ppb 0.14% of reading 0.60% 1 ppb;
0.3%
Methane CH4 0-100
ppm
0.01 ppm 0.02 ppm;
0.3%
0.04 ppm 0.4% of reading 1% 0.04ppm;
1%

 

Particle
module
Particle Sizes Range Display
Resolution
LDL (2σ) Precision Accuracy Zero
Stability
Min. Detect.
Particle Size
PCX1 (Optical
Particle
Counter)
PM1, PM2.5, PM4,
PM10 and TSP
0 – 30,000 μg/m3 0.1 μg/m3 0.1 μg/m3 ± 3% of
reading
< 5% of
reading
± 0.1 μg/m3
over 24 hour
period
50% eff.: 0.3μm
Nephelometer PM1, PM2.5, PM10
OR TSP
0 to 60,000
μg/m3
0.1 μg/m3 <1 μg/m3 ± 1% of
reading
±(2 μg/m3 + 5%
of reading)
± 0.1 μg/m3
over 24 hour
period
Optimal performance
at 0.5 to 10 μm

Additional information

Manufacturer

Aeroqual

Model

AQS 1

Measuring Parameters

PM10, PM4, PM2.5, PM1, TSP, O3, NO2, CO, SO2, H2S, CH4 and VOC

Control system

Embedded PC with on board data storage (>5 years)

Communication

Standard: WIFI, Ethernet (LAN) Optional modem: Cellular IP 4G LTE, Integrated high gain antenna

Averaging period

User selectable averaging interval from 1 min to 24 hr

Operating Temperature

-10 °C to +45 °C (14 °F to 113 °F)

Factory integrated sensors

Gill Wind Sonic (ultrasonic wind sensor), Vaisala WXT536 (weather transmitter), Cirrus MK427 Class 1 (noise sensor), Novalynx
Pyranometer (solar radiation), Airmar 200WX (weather station)

Compatible tested sensors

A wide range of other sensors can be connected including: Victron SmartSolar MMPT 100-20 (solar charge controller), BSWA 308
(sound level meter) and Svantek SV971A (sound level meter). Contact Aeroqual for more information.

Signal inputs and outputs

0-5V analog input, 4-20mA input, configurable relay output

Power 

100-260 VAC or 9-36VDC battery/solar: Power usage: 15 to 30 W max steady state (configuration dependent)

Dimensions

685 mm x 330 mm x 187 mm

Weight

< 13 kg (28.6 lbs)