Fluke 107 Palm sized Digital Multimeter,Palm Sized Multimeter
fluke 107  Digital Multimeter,Digital Multimeter
Digital Multimeter,Palm Sized Digital Multimeter
Fluke 107 Palm sized Digital Multimeter,Palm Sized Multimeter

Fluke 107 Palm-sized Digital Multimeter

Fluke 107 digital multimeter is made to fit the manner in which you work! It is intended to fit in the palm of your hand and go with you no matter where your activity takes you.

Features of Palm Sized Digital Multimeter

Voltage, resistance, continuity, capacitance


Input terminal for ac and dc current estimation to 10 A and current


Backlit display


Data hold


Diode test, plus frequency and duty cycle measurements

Quantity

$88.57
Tax /GST included

Accuracy Specifications


AC Volts 
(40 Hz to 500Hz)1


Range


Resolution


Accuracy


6.000 V
60.00 V
600.0 V


0.001 V
0.01 V
0.1 V


1.0 % + 3


DC Volts


6.000 V
60.00 V
600.0 V


0.001 V
0.01 V
0.1 V


0.5 % + 3


AC Millivolts


600.0 mV


0.1 mV


3.0 % + 3


Diode Test2


2.000 V


0.001 V


10 %


Resistance 
(Ohms)


400.0 Ω
4.000 k
Ω
40.00 k
Ω
400.0 k
Ω
4.000 M
Ω
40.00 M
Ω


0.1 Ω
0.001 k
Ω
0.01 k
Ω
0.1 k
Ω
0.001 M
Ω
0.01 M
Ω


0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3


Capacitance3


50.00 nF
500.0 nF
5.000
μF
50.00
μF
500.0
μF
1000
μF


0.01 nF
0.1 nF
0.001
μF
0.01
μF
0.1
μF
1
μF


2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5


Frequency4
Hz
(10 Hz – 100 kHz)


50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz


0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz


0.1 % + 3


Duty Cycle4


1 % to 99 %


0.1 %


1 % typical 5


AC Current
(40 Hz to 200 Hz)


4.000 A
10.00 A


0.001 A
0.01 A


1.5 % + 3


DC Current


4.000 A
10.00 A


0.001 A
0.01 A


1.5 % + 3


  1. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  2. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
  3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
  4. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  5. Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %
100 Items

Data sheet

Manufacturer
Fluke
Display
LCD
Count modes
6000
Operating Temperature
0 °C to 40 °C
Resistance Measuring Range
0-40 MΩ
Storage Temperature
-30 °C to 60 °C
Operating Altitude
2000 m
Storage Altitude
12,000 m
Safety Rating
IEC 61010-1: 600 V CAT III, Pollution Degree 2
Sensing Method
Average
DC Voltage Measuring Range
0-600 V
AC Current Measuring Range
10A
DC Voltage Accuracy
±0.5% + 3 Digit
AC Voltage Accuracy
±1.0%+3 Digits
AC Current Accuracy
±1.5% + 3 Digit

You might also like