Hospital OT Room Monitor- Model AI-CRM3-1-1

The Hospital Operation Theatre Monitor is designed to measure the vital parameters of Temperature,Humidity & Differential Pressure in Hospital Operation Theatre Room Applications.

Applications: Immense use in Hospitals, Operation Theatres, Medical Labs, Pharma Labs, Green Houses etc.

In Stock
50 Items
$333.25
Quantity

The Hospital OT Monitor is designed to measure the vital parameters of Temperature,Humidity & Differential Pressure in Hospital Operation Theatre room Applications.The Model AI-CRM3-1-1 is designed for minimum cabling & easy flush mounting in Modular Wall or Brick Walls of Hospital Operation Theatre Rooms. The sensor for humidity & temperature is externally provided so that the sensor can be mounted in the Operation Theatre & the Display can be outside the Operation Theatre. The differential pressure sensor is built inside the Hospital Operation Theatre Room Monitor with 2 Nos. Hose Nipples for room & corridor connection .

Easy integration to Building Management Systems ( BMS ) with the RS 485 Modbus RTU Protocol Communication allow easy set up & great control.The Display of the Hospital Operation Theatre Monitor AI-CRM3-1-1 is a large 1” High Super Bright Display with integrated buzzer alarm for process limit violation alert for each of the 3 parameters of temperature , humidity & differential pressure . The display LEDs also show the alarm status for easy identification & follow-up remedial action.

50 Items

Data sheet

Manufacturer
ACE Instruments
Model
AI-CRM3-1-1
Range
1) -30.0 to +50.0 Deg. C typical for Temperature 2) 0.0 to 100.0 %RH typical for Relative humidity 3) 0.0 to +25.0 mm. W.C./ 0 to 250 Pascals (Any other customized range as per user specifications)
Display
3 Line Red 7 Segment LED Display ; 4 Digits for Differential Pressure on Line 1 ; 4 Digits for Temperature ( Deg. C) on Line 2 ; 4 Digits for % R.H. ( Humidity ) on Line 3 All Digit Size: 1 Inch
Differential Pressure Entry
2 Nos. 4 mm. Hose Nipples at top of clean room monitor enclosure
Sensors
1) External Humidity & Temperature Sensor in Stainless Steel Front Flush Plate Enclosure 2) Built-in differential pressure sensor with Brass Hose Nipples (Chrome Plated) for Differential Pressure At Rear ( 4mm x 2 Nos.)
Supply voltage
24VDC , 500mA
Enclosure
M.S. Powder Coated Body with Stainless Steel Front Flush Plate for Modular Wall Mounting /Optional Brick Wall Mounting
Communication
RS 485 Modbus RTU Protocol
Sensor Type
1) Combination External Humidity & Temperature Sensor 2) Built In Piezo Resistive Sensor for Differential Pressure
Buzzer
Integrated buzzer for Alarm Hi & Lo in case of process violation of any of the 3 parameters
Setting
By 4 keys on the front stainless steel panel
Mounting
Wall mounting / Modular Wall mounting with Stainless Steel Front Flush Plate for Clean Rooms
Dimensions
1) Enclosure : 115(W) X 150(H) X 40(D) mm. 2) Stainless Steel Front Plate : 145W x 160 (H) mm
Calibration
Will be provided at no extra cost valid for 1yr traceable to Electronic Test & Development Centre
Warranty
12 Months Manufacturer warranty
Weight
700 gms. Approx.

You might also like

Dr Samar Banerjee
06/17/2017
Best OT Room Monitor:

Best OT Room Monitor i have received. Shipped on time. Good packing.

Write your review