Air Quality Meter, Lutron Air Quality Meter, Air Quality Monitor
Air Quality Meter, Lutron Air Quality Meter, Air Quality Monitor

Lutron Air Quality Meter (AQ-9901SD)

Lutron Air Quality Meter AQ-9901SD offers exact and effective continuous chronicle. The data gets saved into the SD memory card and can be downloaded to Excel. With its exceptional level development, this air quality meter is certain to provide durability.

Quantity

$1,036.05
Tax /GST included

Lutron Air Quality Meter is a Real-time recorder which saves the information into the SD memory card and can be download to the Excel, additional product is no need. Client can make further information or realistic investigation without anyone else's input. under the Excel software. At a similar time, the SD memory card can record 3 test's information ( %RH/CO2/O2/Temp. or on the other hand %RH/CO2/CO/Temp. ) alongside the time data into the one Excel record in the meantime.
 
Features of Lutron Air Quality Meter:
        
• Alarm setting with the beeper sound yield.

• Sampling time for information recorder is 2 seconds to 8 hours.
 
• Complete set with 4 tests : CO2/Temp. test, O2/Temp. test, CO/Temp. probe,Humidity/Temp. test, fundamental meter and the hard conveying case.
 
• Separate test, simple for remote estimation.
 
• Meter can participate with 2 GB to 16 GB SD card, SD card is discretionary.

Remarks:

• Dew Point show esteem is figured from the Humidity/Temp. estimation naturally.
 
• The Dew Point precision is whole exactness estimation of Humidity and Temperature estimation.
 
• Wet globule show esteem is figured from the Humidity/Temp estimation consequently.
 
• The Welt globule precision is aggregate exactness estimation of Humidity and Temperature estimation.
 
Note: If LCD backdrop illumination is on, the power utilization will increment approx 12 mA.

100 Items

Data sheet

Model
AQ-9901SD
Operating Humidity
Less than 80% R.H.
CO ( Carbon dioxide )
Range : 0 to 1,000 ppm || Resolution 1 ppm || Accuracy : ± ( 5% + 2 ppm) || Response < 30 seconds, Sensitivity drift : < 5% per year
Relative Humidity
Range 5 % to 95 % R.H || Resolution 0.1 % R.H || Accuracy 70% RH : ± (3% reading + 1% RH) , < 70% RH : ± 3% RH
O2 ( Air oxygen )
Range : 0 to 30 %O2 || Resolution : 0.1 %O2 || Accuracy : ± ( 1 % reading + 0.2 % O2 ) @ After calibration || Response time : 15 seconds. ≦ @ t 90 || Overload protection :100 %O2 || Environment pressure range : 0.9 to 1.1 atmosphere || Expected life : 2 y
Wet bulb Temp. ( Humidity )
Range : -21.6℃ to 50.0 ℃ || Resolution : 0.1 ℃ & Range : -6.9℉ to 122.0 ℉ || Resolution 0.1℉
Sensors
CO2 : NDIR * Nondispersive infrared sensor, Humidity : Precision capacitance sensor, O2: Galvanic cell type, CO : Galvanic cell type, Temp. Precision thermistor
Circuit
Custom one-chip of microprocessor LSI circuit.
Data Hold
Freeze the display reading
Sampling Time
Sampling Time of Display : Approx. 1 second
Temperature
Range : 0℃ to 50℃ ,32℉ to 122℉ || Resolution : 0.1 degree || Accuracy : ± 0.8 ℃, ± 1.5 . ℉
Power Supply
AAlkaline or heavy duty DC 1.5 V battery( UM3, AA ) x 6 PCs, or equivalent || ADC 9V adapter input. ( AC/DC power adapter is optional )
Optional
Optional Accessories : SD memory card ( 2 GB ), AC to DC 9V adapter, USB cable, USB-01, RS232 cable, UPCB-02, Data Acquisition software, SW-U801-WIN
Memory
SD memory card. 1 GB to 16 GB.
Accessories
Accessories included : Instruction manual, Hard carrying case, CA-08, CO2 probe, Humidity probe, O2 probe, CO probe
Memory Recall
Maximum & Minimum value
Data Output
RS 232/USB PC computer interface.
Dimensions
Meter : 177 x 68 x 45 mm , Humidity 197 mm in length , CO2 : probe 190 x 38 x 28 mm , O2 : probe 150 x 38 x 38 mm , CO : probe 150 x 38 x 38 mm
Weight
350 g/0.77 LB