Lutron Air Quality Meter (AQ-9901SD)

Lutron Air Quality Meter offers precise and efficient real-time recording. The data gets saved into the SD memory card and can be downloaded to Excel. With its premium grade construction, this air quality meter is sure to provide durability.

Quantity

$1,060.70
Tax /GST included

Lutron Air Quality Meter is a Real time recorder which save the data into the SD memory card and can be down load to the Excel, extra software  is no need. User can make the further data or graphic analysis by themselves. under the Excel software.At the same time, the SD memory card can record 3 probe's data ( %RH/CO2/O2/Temp. or %RH/CO2/CO/Temp. ) along with the time information into the one Excel file at the same time.

Features: 

• Alarm setting with the beeper sound output
• Sampling time for data recorder is 2 seconds to 8 hours
• Complete set with 4 probes : CO2/Temp. probe, O2/Temp. probe, CO/Temp. probe,Humidity/Temp. probe, main meter and the hard carrying case
 Separate probe, easy for remote measurement.
• Meter can cooperate with 2 GB to 16 GB SD card, SD card is optional.

Remarks:

• Dew Point display value is calculated from the Humidity/Temp. measurement automatically
• The Dew Point accuracy is sum accuracy value of Humidity & Temperature measurement
• Wet bulb display value is calculated from the Humidity/Temp measurement automatically
• The Welt bulb accuracy is sum accuracy value of Humidity & Temperature measurement

Note: If LCD backlight is on, the power consumption will increase approx 12 mA

50 Items

Data sheet

Model
AQ-9901SD
Operating Humidity
Less than 80% R.H.
CO ( Carbon dioxide )
Range : 0 to 1,000 ppm || Resolution 1 ppm || Accuracy : ± ( 5% + 2 ppm) || Response < 30 seconds, Sensitivity drift : < 5% per year
Relative Humidity
Range 5 % to 95 % R.H || Resolution 0.1 % R.H || Accuracy 70% RH : ± (3% reading + 1% RH) , < 70% RH : ± 3% RH
O2 ( Air oxygen )
Range : 0 to 30 %O2 || Resolution : 0.1 %O2 || Accuracy : ± ( 1 % reading + 0.2 % O2 ) @ After calibration || Response time : 15 seconds. ≦ @ t 90 || Overload protection :100 %O2 || Environment pressure range : 0.9 to 1.1 atmosphere || Expected life : 2 y
Wet bulb Temp. ( Humidity )
Range : -21.6℃ to 50.0 ℃ || Resolution : 0.1 ℃ & Range : -6.9℉ to 122.0 ℉ || Resolution 0.1℉
Sensors
CO2 : NDIR * Nondispersive infrared sensor, Humidity : Precision capacitance sensor, O2: Galvanic cell type, CO : Galvanic cell type, Temp. Precision thermistor
Circuit
Custom one-chip of microprocessor LSI circuit.
Data Hold
Freeze the display reading
Sampling Time
Sampling Time of Display : Approx. 1 second
Temperature
Range : 0℃ to 50℃ ,32℉ to 122℉ || Resolution : 0.1 degree || Accuracy : ± 0.8 ℃, ± 1.5 . ℉
Power Supply
AAlkaline or heavy duty DC 1.5 V battery( UM3, AA ) x 6 PCs, or equivalent || ADC 9V adapter input. ( AC/DC power adapter is optional )
Optional
Optional Accessories : SD memory card ( 2 GB ), AC to DC 9V adapter, USB cable, USB-01, RS232 cable, UPCB-02, Data Acquisition software, SW-U801-WIN
Memory
SD memory card. 1 GB to 16 GB.
Accessories
Accessories included : Instruction manual, Hard carrying case, CA-08, CO2 probe, Humidity probe, O2 probe, CO probe
Memory Recall
Maximum & Minimum value
Data Output
RS 232/USB PC computer interface.
Dimensions
Meter : 177 x 68 x 45 mm , Humidity 197 mm in length , CO2 : probe 190 x 38 x 28 mm , O2 : probe 150 x 38 x 38 mm , CO : probe 150 x 38 x 38 mm
Weight
350 g/0.77 LB

You might also like