Fluke 106 Palm-sized Digital Multimeter

Fluke 106 Digital Multimeter combines the testing capabilities of single-task meters like that of the voltmeter, ammeter and ohmmeter.

Applications: Electronic engineers and technicians widely use this piece of test equipment mainly to measure the three basic electrical aspects called voltage, current and resistance. It can also be used to test continuity between two points in an electrical circuit.

Quantity

$52.54
Tax /GST included

Features:

  • Safety rating by CAT III 600 V
  • AC/DC current, AC/DC voltage, resistance, capacitance measurement.
  • Large, easy to read backlit display.
  • Small lightweight design - easy carrying in pocket.
  • Rugged, reliable, exact readings.
  • Long battery life with auto power off.

Technical Specifications:

Accuracy Specifications

Function

Range

Resolution

Accuracy

AC Volts1

6.000 V
60.00 V
600.0 V

0.001 V
0.01 V
0.1 V

1.0 % + 3

DC Volts

6.000 V
60.00 V
600.0 V

0.001 V
0.01 V
0.1 V

0.5 % + 3

AC Millivolts

600.0 mV

0.1 mV

3.0 % + 3

Diode Test2

2.000 V

0.001 V

10 %

Resistance 
(Ohms)

400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ

0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ

0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3

Capacitance3

50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF

0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF

2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5

Frequency4 Hz
(10 Hz – 100 kHz)

50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz

0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz

NA

Duty Cycle4

1 % to 99 %

0.1 %

NA

AC Current
(40 Hz to 200 Hz)

4.000 A
10.00 A

0.001 A
0.01 A

1.5 % + 3

DC Current

4.000 A
10.00 A

0.001 A
0.01 A

1.5 % + 3

1.     All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.

2.     Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.

3.     Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).

4.     All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.

Function

Overload Protection

Input Impedance (Nominal)

Common Mode Rejection Ratio

Normal Mode Rejection Ratio

AC Volts

600 V 1

>10 MΩ <100 pF 2

>60 dB at dc,
50 Hz or 60 Hz

AC Millivolts

600 mV

>1M, <100 pF

>80 dB at 50 Hz or 60 Hz

DC Volts

600 V 1

>10 MΩ <100 pF

>100 dB at dc,
50 Hz or 60 Hz

>60 dB at 50 Hz or 60 Hz

50 Items

Data sheet

Manufacturer
Fluke
Model
Fluke 106
Display
6000 counts, updates 3/sec
Maximum voltage between any terminal and earth ground
600 V
Operating Temperature
0 °C to 40 °C
Operating Humidity
Non-condensing when
Battery Life
200 hours minimum
Temperature coefficient
0.1 X (specified accuracy) /°C (28 °C)
Electromagnetic environment
IEC 61326-1: Portable
Storage Temperature
-30 °C to 60 °C
Operating Altitude
2000 m
Storage Altitude
12,000 m
Accessories
TL75 Test leads , 2 AAA Batteries (installed), User manual.
Safety rating
IEC 61010-1: 600 V CAT III, Pollution Degree 2
Fuse Protection
0.1 X (specified accuracy) /°C (28 °C)