Fluke 115 Digital Multimeter

The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications. This true-rms meter provides easy one-handed operation in a compact package.

Quantity

$136.91
Tax /GST included

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ± ( [ % of reading ] + [ counts ] )

Features :

• Resistance, continuity, frequency, capacitance, and diode test

• Measures 10 A (20 A overload for 30 seconds)

• Large white LED backlight to work in poorly lit areas

• Compact ergonomic design for one-handed operation

• Compatible with optional magnetic hanger (ToolPak™)

• True-rms for accurate measurements on non-linear loads

Measurement

Range

Resolution

Accuracy ± ([% of reading] + [counts])

DC millivolts

600.0 mV

0.1 mV

0.5 % + 2

DC volts

6.000 V

0.001 V

0.5 % + 2

60.00 V

0.01 V

600.0 V

0.1 V

Auto volts

600.0 V

0.1 V

2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz)

AC millivolts1 true-rms

600.0 mV

0.1 mV

1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)

AC volts1 true-rms 6

6.000 V

0.001 V

1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)

60.00 V

0.01 V

600.0 V

0.1 V

Continuity

600 Ω

1 Ω

Beeper on < 20 off > 250 ; detects opens or shorts of 500 µs or longer.

Ohms

600.0 Ω

0.1 Ω

0.9 % + 1

6.000 kΩ

0.001 kΩ

60.00 kΩ

0.01 kΩ

600.0 kΩ

0.1 kΩ

6.000 MΩ

0.001 MΩ

40.00 MΩ

0.01 MΩ

Diode test

2.000 V

0.001 V

 

Capacitance

1000 nF

1 nF

1.9 % + 2

10.00 µF

0.01 µF

100.0 µF

0.1 µF

9999 µF

1 µF

100 µF to 1000 µF

 

> 1000 µF

 

 

Lo-Z capacitance 1

1 nF to 500 µF

10 % + 2 typical

 

AC amps true-rms (45 Hz to 500 Hz)

6.000 A

0.001 A

1.5 % + 3

10.00 A

0.01 A

20 A overload for 30 seconds max.

 

 

DC amps

6.000 A

0.001 A

1.0 % + 3

10.00 A

0.01 A

20 A overload for 30 seconds max

 

99.99 Hz

0.01 Hz

0.1 % + 2

999.9 Hz

0.1 Hz

9.999 kHz

0.001 kHz

50.00 kHz

0.01 kHz

• Min/Max/Average with elapsed time to record signal fluctuations

 • CAT III 600 V safety rated

50 Items

Data sheet

Manufacturer
Fluke
Model
Fluke 115
Display
Digital: 6,000 counts, updates 4/sec
Maximum voltage between any terminal and earth ground
600 V
Battery
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Operating Temperature
-10 °C to + 50 °C
Battery Life
400 hours typical, without backlight
Storage Temperature
-40 °C to + 60 °C
Surge protection
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Bar graph
33 segments, updates 32/sec
Fuse for A input
11 A, 1000 V FAST Fuse (Fluke PN 803293)

You might also like