Amprobe Insulation Tester
Amprobe Insulation Resistance Tester
Amprobe Insulation Tester

Amprobe AMB-50 Basic Insulation Resistance Tester

Amprobe AMB-50 High-Voltage Insulation Tester has the necessary features for professional insulation diagnostics.

Application:Maintenance, & commissioning and industrial/OEM.

Quantity

$787.80
Tax /GST included

It features calculation of PI, and DAR parameters Readings are clearly displayed on a large backlit LCD display. Windows compatible PC Software and USB communications port serve for connecting the instrument to the PC and management of the recorded test data.

  • Test insulation of wires, cables, transformers, motors, surge arrestors and generators
  • Selectable testing voltages - one testing instrument for low and high voltage systems from 500/1000/2500 and 5000V
  • Dual power source – receptacle or batteries Built in internal memory storing 18 measurements
  • CAT III 600V

Technical specification:

Insulation Resistance

500V 1000V 2500V 5000V

Range

0.5 MΩ – 20GΩ 2 MΩ – 40GΩ 5MΩ – 100GΩ 100 MΩ – 1000GΩ

Open Circuit Voltage

DC 500V 0%~+20% DC 1000V 0%~+20% DC 2500V 0%~+20% DC 5000V 0%~+20%

Test Current

1mA~1.2mA @ 500kΩ 1mA~1.2mA @ 1MΩ 1mA~1.2mA @ 2.5MΩ 1mA~1.2mA @ 5MΩ

Accuracy

500V

0.50M ~99.9M : (3%+5) 100M ~9.99G : (5%+5) 10.0G ~20.0G : (10%+5)

1000V

2.0M ~99.9M : (3%+5) 100M ~9.99G : (5%+5) 10.0G ~40.0G : (10%+5)

2500V

5.0M ~99.9M : (3%+5) 100M ~9.99G : (5%+5) 10.0G ~100G : (10%+5)

5000V

10.0M ~29.9M : (For reference only) 30.0M ~99.9M : (3%+5) 100M ~9.99G : (5%+5) 10.0G ~99.9G : (10%+5) Above 100G : [ (20%+5) Humidity :Below 50%]

100 Items

Data sheet

Manufacturer
Amprobe
Model
AMB-50
Display
1999 counts. Analog bar graph.
Operating Temperature
-10°C~40°C (14°F ~104°F )
Relative Humidity
< 85% @ -10°C ~40°C below; < 90% @ 0°C ~40°C :
Battery Life
8pcs X 1.5V (LR14) batteries or power adaptor (input voltage 230V, 50/60Hz, 75mA, input DC14V, 1.0A). Power adaptor is not included
Storage Temperature
-20°C ~60°C (-4 °F~152°F )
Storage Conditions
20°C to 60°C, 0 to 70% R.H. with battery removed from meter
Dimension
220(L) X 155 (W) X94(H)mm (7.95 X 6.1 X 3.7 inch)
Weight
Approx. 2kg (4.4 Lbs) (including battery)