ABB TTH200 Temperature Transmitter, ABB Head Mount Temperature Transmitter
Temperature Transmitter, 
Field mount temperature transmitter
ABB TTH200 Temperature Transmitter, ABB Head Mount Temperature Transmitter

ABB TTH200 Temperature Transmitter

ABB TTH200 Temperature Transmitter type is designed for standard type B sensor heads. TTH200 is provided for all HART standard applications in temperature measurement with one sensor. The transmitter supports the same functionality as the TTH300, but without sensor redundancy and sensor drift monitoring and can be configured via FDT / DTM in DAT200 (Asset Vision Basic) or any standard FTD tool via EDD.

Applications: Temperature measurement in air, soil, or water,measurement of delicate surfaces (e.g., leaves, fruits), Oil, Gas and Petrochemical, Research and Development, Industrial Safety, Hazardous Areas and pharmaceutical

Standard Model:  ABB TTH200.Y0.H.BS

Quantity

$254.20
Tax /GST included

The ABB TTH200 Temperature Transmitter type is designed for standard type B sensor heads. The advantage increased measuring accuracy resulting from conversion of the sensor signal into a stable output signal close to the sensor. For thermocouple applications without compensation cables.

50 Items

Data sheet

Manufacturer
ABB
Model
Standard Model: ABB TTH200 Temperature Transmitter
Output
standard: 4-20 mA ; configurable: 20-4 mA
Display
Standard Supply Without Display
Cable Connection
Maximum sensor line resistance (RW) for each line: 1.5 kΩ, total: 3 kΩ
Storage Temperature
-50 … 85 °C (-58 … 185 °F)
Electrical Connection
Electrical connection Terminals (captive screws) incl. soldering tags
Input
Resistance RTD Pt-100, Thermocouples B,E, J, K, N, R,S, T, Voltages, mV Voltages
Voltage
-125 ... 125 mV ; -125 ... 1100 mV
Ambient temperature
Standard: -40 … 85 °C (-40 … 185 °F) ; Optional: -50 … 85 °C (-58 … 185 °F)
Electrical Interface
3.5 kV DC (approx. 2.5 kV AC) 60 s, input to output
Vibration Resistance
10 … 2,000 Hz at 5 g in acc. with IEC 60068-2-6, during operation and transport
Power Supply
11-42 VDC
Housing
Polycarbonate
Warm-up Time
5 minutes
Communication
HART protocol
Calibration
Provided alongwith and valid for 1 year, traceable to National Standards
Input resistance
> 10 MΩ