GE Telaire T5100 CO2 Transmitter
₹15,983.05
(GST 18% Exclusive)
2213
(However please contact store for precise delivery schedule. Backorder also allowed)
GE Telaire T5100 CO2 Transmitter series is a minimal effort, high performing CO2 transmitter for the Building controls advertise. It works consistently with building mechanization frameworks and enables you to just and adequately control natural air. Request controlled ventilation utilizing CO2 sensors prevents energy losses from over-ventilation while keeping up indoor air quality.
Applications: HVAC, Greenhouse, Landfill gas, Confined space, Marine vessels, Ventilation, Management, Mining, cellar & gas stores, Buildings, Bus, Railway waiting halls, Schools, Library, Trains, Hospitals, Office, Subway.
Products related to this item
-
₹20,468.00
(GST 18% Exclusive)
Lutron GC-2028 Carbon Dioxide Meter
-
₹15,929.66
(GST 18% Exclusive)
Honeywell CDS2000A1000C Carbon Dioxide Gas Detector
-
₹7,020.00 – ₹7,950.00
(GST 18% Exclusive)
Ace AI-CO2 Series Carbon Dioxide Transmitter
-
₹9,970.34
(GST 18% Exclusive)
Senseair Carbon Dioxide (CO2) Transmitter
Features of the GE Telaire T5100 CO2 Transmitter:
- Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package.
- Patented ABC Logic™ self-calibration system eliminates the need for manual calibration in most applications.
- Lifetime CO2 calibration guarantee when using ABC Logic™.
- Mounting plate with two-piece terminal blocks provides quick, easy wiring.
- Gas permeable, water-resistant CO2 diffusion filter prevents particulate and water contamination of the sensor.
- Sensors are shipped factory calibrated.
- Modern enclosure.
- Reliable (20 years of low-cost infrared sensor manufacturing).
- Available output options: Voltage 0-10V or 0-5V (jumper selectable) Or current 4-20 mA.
- UIP software is compatible with customizations.
Additional information
Weight | 1 kg |
---|---|
Manufacturer | Telaire by GE (General Electric) |
Model No | T5100 |
Measuring Parameters | CO2 |
Range | 0 to 2000 ppm |
Accuracy | ± 30 ppm or 3% of the reading shown,whichever is higher* |
CO2 Warm-Up Time | <2 minutes (operational) |
Analog (CO2) | • 0 to 5 V, or 0 to 10 V jumper selectable (100 Ω output impedance) |
Output | Field selectable voltage or current Voltage only (0-10 or 0-5V)- Current only (4-20 mA) |
Signal Update | Every 5 seconds |
Operating Temperature | 0°C to 50°C |
Storage Temperature | -40°F to 158°F (-40°C to 70°C) |
Operating Humidity | 0 to 95% RH, non-condensing |
Temperature Dependance | 0.2% FS per °C (±0.11% per °F) |
Pressure dependency | 0.135% of reading per mm Hg |
Sensing Method | Non-dispersive infrared (NDIR) absorption gold plated optics Patented ABC Logic self Calibration algorithm |
Power Supply | 18-30 VAC RMS, 50/60 Hz, or 18 to 42 VDC, polarity protected |
Power Consumption | Typical 0.7 W at normal voltage of 24V AC RMS |
Flammability Classification | UL94 5VA |
Stability | <2% of FS over life of sensor (15 years) |