Ace 8 Channel Data Logger is used to measure & record various parameters like vacuum, pressure, temperature, humidity & differential pressure on different channels up to 8 in a single instrument. This Multi-Channel Datalogger also acts as a paperless recorder, hence saving sample time in recording and analyzing data.
Applications: Temperature recording applications in industry, scientific research, quality assurance applications, research, and development.

Clear

Ace 8 Channel Data Logger can measure 8 inputs at a time on its 8 channels. These 8 inputs can be one type (eg: say, all 8 inputs can be a vacuum, pressure, temperature, etc.). or of different types (e.g., Channel 1 for humidity, Channel 2 for temperature, Channel 3 for differential pressure, and so on). Alternatively, this multi-channel data logger can be used to read and record any 1 input on any 1 channel, and the remaining channels can be disabled using the front keys. Similarly, any number of channels can be enabled and disabled to render the instrument as a 1 channel, 2 channel, 3 channel, 4 channel, 5 channel, 6 channel, 7 channel, or 8 channel instrument.
Features of Ace 8 Channel Data Logger:

  • Multi-Channel Scanner: This multi-channel scanner can be used as a plane scanner where the only purpose of the instrument is to display the input value from the sensors.
  • Scanner With Printer Port: This Paperless recorder offers a parallel printer port for printing directly onto an 80/132 channel printer without using a computer. The print interval(time gap between Successive Printouts) can be controlled by using the front keys.
  • Scanner with Memory(Data Logger): This instrument can be provided with 5000 readings memory built-in for each of the 8 Channels and provided with any standard communication port(RS 232 or RS485) for computer connectivity. The fully loaded Data Logger comes with Parallel Printer Port for direct printing onto an 80/132 column Dot Matrix Printer, 5000 reading memory, and any one communication port of your choice.

Additional information

Weight 1.5 kg
Manufacturer

Ace Instruments

Model No

AI-800 series

Display

1 Digit for Channel No. ; 4 Digits for Process Variable

Input

8 Nos. of Vacuum / Pressure / Humidity (4-20 mA),Temperature (4-20 mA) RTD Pt-100 Sensors,0 -1/ 0-5 / 0-10 V DC, Any Standard Thermocouple,(To be specified at time of ordering)

Accuracy

+/- 0.25% of Full Scale.

Communication

RS 232 / RS485 /USB Computer Connectivity Output & Optional Direct 80 Column Dot Matrix Printer Port

Memory

5000 Records of Each of the 8 Channels

Modes

Channel Skip , Hold & Auto Modes

Scan Time

1 to 59 seconds ( User Programmable )

Relay/ Alarm

2 Relay Contacts for Alarm & Trip

Power Supply

230 V.A.C., 50 Hz, Single Phase / Optional 24 V.D.C.

Calibration

Provided alongwith and valid for 1 year, traceable to National Standards.

Warranty

1 Year Manufacturer Warranty

Dimension

96 X 96 X 175 mm

Weight

800 Grams