Ace 8 Channel Data Logger (FDA 21 CFR)
₹23,290.00 – ₹72,500.00
(GST 18% Exclusive)
2261
2261
(However please contact store for precise delivery schedule. Backorder also allowed)
Ace 8 Channel Data Logger is used to measure & record various parameters like vacuum, pressure, temperature, humidity & differential pressure on different channels up to 8 in a single instrument. This Multi-Channel Datalogger also acts as a paperless recorder, hence saving sample time in recording and analyzing data.
Applications: Temperature recording applications in industry, scientific research, quality assurance applications, research, and development.
Products related to this item
-
₹32,987.29
(GST 18% Exclusive)
Supco DVT4 4 channel temperature datalogger
-
₹12,768.64
(GST 18% Exclusive)
Autonics T4WM-N3NP4C 5-Channel Digital Temperature Indicator
-
₹35,525.00 – ₹81,950.00
(GST 18% Exclusive)
Ace 16 Channel Data Logger (FDA 21CFR)
-
₹39,155.00
(GST 18% Exclusive)
Ace AI-800-FLP Flameproof 8 Channel Universal Data Logger
Ace 8 Channel Data Logger can measure 8 inputs at a time on its 8 channels. These 8 inputs can be one type (eg: say, all 8 inputs can be a vacuum, pressure, temperature, etc.). or of different types (e.g., Channel 1 for humidity, Channel 2 for temperature, Channel 3 for differential pressure, and so on). Alternatively, this multi-channel data logger can be used to read and record any 1 input on any 1 channel, and the remaining channels can be disabled using the front keys. Similarly, any number of channels can be enabled and disabled to render the instrument as a 1 channel, 2 channel, 3 channel, 4 channel, 5 channel, 6 channel, 7 channel, or 8 channel instrument.
Features of Ace 8 Channel Data Logger:
- Multi-Channel Scanner: This multi-channel scanner can be used as a plane scanner where the only purpose of the instrument is to display the input value from the sensors.
- Scanner With Printer Port: This Paperless recorder offers a parallel printer port for printing directly onto an 80/132 channel printer without using a computer. The print interval(time gap between Successive Printouts) can be controlled by using the front keys.
- Scanner with Memory(Data Logger): This instrument can be provided with 5000 readings memory built-in for each of the 8 Channels and provided with any standard communication port(RS 232 or RS485) for computer connectivity. The fully loaded Data Logger comes with Parallel Printer Port for direct printing onto an 80/132 column Dot Matrix Printer, 5000 reading memory, and any one communication port of your choice.
Additional information
Weight | 1.5 kg |
---|---|
Manufacturer | Ace Instruments |
Model No | AI-800 series |
Display | 1 Digit for Channel No. ; 4 Digits for Process Variable |
Input | 8 Nos. of Vacuum / Pressure / Humidity (4-20 mA),Temperature (4-20 mA) RTD Pt-100 Sensors,0 -1/ 0-5 / 0-10 V DC, Any Standard Thermocouple,(To be specified at time of ordering) |
Accuracy | +/- 0.25% of Full Scale. |
Communication | RS 232 / RS485 /USB Computer Connectivity Output & Optional Direct 80 Column Dot Matrix Printer Port |
Memory | 5000 Records of Each of the 8 Channels |
Modes | Channel Skip , Hold & Auto Modes |
Scan Time | 1 to 59 seconds ( User Programmable ) |
Relay/ Alarm | 2 Relay Contacts for Alarm & Trip |
Power Supply | 230 V.A.C., 50 Hz, Single Phase / Optional 24 V.D.C. |
Calibration | Provided alongwith and valid for 1 year, traceable to National Standards. |
Warranty | 1 Year Manufacturer Warranty |
Dimension | 96 X 96 X 175 mm |
Weight | 800 Grams |
Reviews