• GrayWolf Direct Sense-II  Particle Counter

    Graywolf Direct Sense-II  Particle Counter, Advanced Sense™ and Wolf Pack™ monitors interface with Gray Wolf 6 channel handheld particle counters and with Thermo Scientific™ pDR particulate concentration meters. Display and log particulates right on the Gray Wolf instrument or mobile PC.

    Applications: Occupational Health and Safety, Cleanroom Monitoring, HVAC, and Research and Development etc

  • Bosch GOL 26 D Professional Level(Discontinued Model..Alternative Model is Bosch GOL-32D Professional Level))

    Bosch GOL 26 D Professional Level robust design with built-in target collimator and the integrated circular vial is specially designed for outdoor use due to sturdy metal housing with dust and splash protection (IP54)Enhance the precision, ease, and efficiency of your work.

  • GE Druck RPS/DPS 8100 Pressure Transducer

    GE Druck RPS/DPS 8100 pressure transducer incorporates the latest TERPS technology. Using a resonant silicon sensor technology platform, it delivers accuracy and stability that is an order of magnitude greater than current pressure measurement technologies. The use of optimized resonator geometry, allows it to operate in even the harshest environments product line takes advantage of best practices to offer a wide range of pressure and electrical connections to enable a level of customization for your specific requirements never before available in the performance class of this sensor.
    Applications of GE Druck pressure Transducers: Oil & Gas, Oceanography, Aerospace, Hydrology, Power Generation, Industrial, Military.

  • Rotronic HL-RC-B Wireless Data Logger

    Rotronic HL-RC-B Wireless Data Logger is designed to measure the Temperature & Humidity (or) Only Temperature as per the user requirement with the highest precision. This Industrial Data logger saves the measured values in the logger and transmits these values to the ROTRONIC HW4 software. This Environmental Data logger offers the highest data integrity and flexibility in use.
    Applications: Pharmaceutical and food industries, mechanical engineering, meteorology, environmental engineering, museums/glass cabinets, research, monitoring of storerooms, chemical industry, and development.

  • Rotronic RMS-LOG-T30-868 Datalogger

    Rotronic RMS-LOG-T30-868 Datalogger is a data logger with two integrated analog-to-digital converters, where for high-precision temperature measurement two PT100 sensors can be connected. The measuring accuracy of this Rotronic Datalogger with PT100 can be improved by a 1- or 2-point adjustment. This Temperature and Humidity Datalogger stores 44,000 pairs of measured values and sends them to the RMS database via LAN or wireless interface.
    Applications: Climate cabinet, Pharmaceutical industry, lean rooms

  • Rotronic Hygrolog- HL-NT3 Temperature Humidity data logger

    Rotronic Hygrolog- HL-NT3 Temperature Humidity data logger and dew point can be used with any of the HygroClip 2 probes. This data logger can monitor up to 7 probes as well as up to two external on/off contacts. When used together with the validated ROTRONIC HW4 software, the HygroLog HL-NT data logger complies with FDA 21 CFR part 11 electronic signatures (ERES) and regarding electronic data records.

    Applications: Clean rooms, production areas, storerooms, residential, office rooms, server rooms, and shipping

  • Elitech TI-40 LCD Temperature Electronic Indicator

    Elitech TI-40 LCD Temperature Indicator is used in places that require high waterproof grade in cold chain storage and transportation. This TI-40 LCD Temperature Indicator is used to measure the temperature range from -30 ℃ to 70 ℃ and results will be displayed on the LCD Screen.

    Application: Pharmaceuticals, vaccines, blood, food, flowers, plants, and laboratories.

  • Dräger Polytron IR N2O Fixed Gas Detector

    Dräger Polytron IR N2O Fixed Gas Detector for the continuous monitoring of nitrous oxide in the ambient air. Its measuring range of full-scale deflection can be configured between 300 and 1000 ppm.

  • Shinyei OMX Series Handheld Odor Meter

    Brand:Shinyei

    Shinyei OMX Series Handheld Odor Meter is a specified tool for the Odor analysis. It Indicates the relative strength and odor classification numerically by comparing odor gas and purified air. The values shown on display are calculated based on the original principle.

    Application: Agriculture, Chemical manufacturing, Cosmetics manufacturing, Pharmaceutical manufacturing, Waste management

  • Drager Gas Detector Tubes and Pump

    Drager Gas Detector Tubes and Pump are very reliable in use even with complex compounds and mixtures of substances. This Drager Tube pump allows you to use the established Drager Tubes to take measurements under extreme conditions. These Drager Tubes have already been calibrated for simple to use and form a perfect unit with the Drager Tube pump.
    Applications: Petroleum Industries, chemical Industries, refining, environmental, metallurgy, gas transmission and distribution, biochemical medicine, agricultural and other industries.

  • MSR MC2 NH3 Gas Sensor Transmitter

    MSR MC2 PH3 Gas Sensor Transmitter houses a module with µController, analog output and power supply in addition to the electrochemical sensor element including amplifier. The µController calculates a linear 4 – 20 mA (or 2 – 10 V) signal out of the measurement signal and also stores all relevant measured values and data of the sensor element.

    Applications:

    The µGard®2 Sensor MC2 is used for the detection of toxic gases or for oxygen monitoring wherever a typical 4 – 20 mA (or 2 – 10 V) signal is required.

  • Dwyer AT22000 Flameproof Magnehelic® Differential Pressure Gauge

    Dwyer AT22000 Flameproof Magnehelic® Differential Pressure Gauge is now available in a flame-proof enclosure with the new ATEX/IECEx approved AT22000 Series. This gage can indicate positive, negative, or differential pressures and is accurate within 2%.
    Applications: Fan and blower pressures, filter resistance, Air velocity, Furnace draft, Liquid levels with bubbler systems, Pressure in fluid amplifier or fluidic systems